{"product_id":"mzx-e-extinguishing-control-panel-english-arabic","title":"MZX-e Extinguishing Control Panel English \/ Arabic - 508.033.050.EA","description":"\u003cp\u003eThe MZX-e extinguishing control panel is powerful yet user-friendly and is designed and manufactured to a high standard. The panel features approval to BS EN 12094- 1:2003, BS EN 54-2 and 4 and is designed to BS 7273 part 1. The panel has extensive configuration options but is easy to install, programme and operate. The removable chassis enables the engineer to “first fix” an empty cabinet and then fit the chassis at the commissioning stage. There is a comprehensive range of accessories available to meet most customer requirements.\u003c\/p\u003e\n\u003ch2\u003eOperation\u003c\/h2\u003e\n\u003cp\u003eThree fully-monitored detection zones are provided. Zones 1 and 2 normally provide first stage and second stage fire conditions to allow extinguishant discharge (coincidence detection zones). Zone 3 is an auxiliary zone for detection only purposes. Zone 4 is used as a manual release zone.\u003c\/p\u003e\n\u003ch2\u003eFacilities\u003c\/h2\u003e\n\u003cp\u003eThree fully-monitored alarm circuits are provided, each rated at 0.5A with various configuration options via the engineers DIL switch settings. Two circuits are designed to provide audible warning of any fire condition and one circuit to provide an individually distinct audible warning of the pre-discharge, discharged and emergency hold condition. Two fully-monitored actuator\/solenoid circuits, each rated at 1A, operate simultaneously upon “extinguishant release”. An RS485 multi-drop circuit link supports up to 7 Status Controller\/Indicators of any type mixed on the communication path. Additional terminals and configuration options allows the engineer to configure the manual release, abort and hold switches to either data comms or hard wired inputs as required.\u003c\/p\u003e\n\u003cp\u003eNormally-open inputs provide for remote evacuate, silence alarms, system reset, lock-off input, low pressure and gas discharged pressure switch input.\u003c\/p\u003e\n\u003cp\u003eOutputs are provided for first stage signalling, second stage signalling, system discharged, common fire and common fault. These outputs may be configured as either Volt-Free C\/O contacts or monitored 24 V (50 mA) outputs. A system reset Volt-Free relay is also provided.\u003c\/p\u003e\n\u003ch2\u003eFeatures:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eApproval to BS EN 12094-1:2003 additional options\u003c\/li\u003e\n\u003cli\u003eApproval to BS EN 54-2 and 4\u003c\/li\u003e\n\u003cli\u003eDesigned to BS7273-1:2000\u003c\/li\u003e\n\u003cli\u003eComprehensive gaseous extinguishing system support\u003c\/li\u003e\n\u003cli\u003eMonitored inputs for gas discharged, gas low, isolation valve closed\/abnormal, gas trapped in manifold\u003c\/li\u003e\n\u003cli\u003eControl inputs for auto\/manual, gas hold, gas abort\u003c\/li\u003e\n\u003cli\u003e1 minute actuator cut off option\u003c\/li\u003e\n\u003cli\u003eMonitored actuator\/solenoid release\u003c\/li\u003e\n\u003cli\u003eExtensive disablement options\u003c\/li\u003e\n\u003cli\u003eCommon fire, fault, relay \/ monitored output facilities\u003c\/li\u003e\n\u003cli\u003e1st, 2nd, 3rd stage and gas discharged relay \/ monitored output facilities\u003c\/li\u003e\n\u003cli\u003eReset relay facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConfiguration:\u003c\/h2\u003e\n\u003cp\u003eThe use of DIL switches on the internal motherboard\u003cbr\u003eenables the engineer to easily configure the extensive\u003cbr\u003eoptions available and view the panel’s configuration upon\u003cbr\u003eany return visit.\u003c\/p\u003e\n\u003ch2\u003eAdditional Benefits:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically safe barrier settings\u003c\/li\u003e\n\u003cli\u003eMetron or solenoid compatible\u003c\/li\u003e\n\u003cli\u003eSingle or double knock operation\u003c\/li\u003e\n\u003cli\u003ePre-discharge delay adjustable from 0 to 60 seconds\u003c\/li\u003e\n\u003cli\u003eDischarged indication with or without pressure switch\u003c\/li\u003e\n\u003cli\u003eInhibit silence alarms until gas discharged\u003c\/li\u003e\n\u003cli\u003eLatching or non latching fault indication option\u003c\/li\u003e\n\u003cli\u003eOption for rapid buzzer pulse when gas discharge is imminent\u003c\/li\u003e\n\u003cli\u003eOne man zone and sounder test\u003c\/li\u003e\n\u003cli\u003eEasily removable chassis\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zettler","offers":[{"title":"Default Title","offer_id":57044332970329,"sku":"508.033.050.EA","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/Image_placeholders__Zettler.png?v=1767725048","url":"https:\/\/ifp-uk.com\/products\/mzx-e-extinguishing-control-panel-english-arabic","provider":"International Fire Protection","version":"1.0","type":"link"}