{"product_id":"fw-tt-2-front-film-tt-2-for-2-detectors-ad-10-1210","title":"FW-TT-2 Front Film TT-2 for 2 detectors - AD-10-1210","description":"\u003cp\u003eThanks to a combination of highly sensitive HPLS optical technology and LOGIC.SENS fire pattern recognition, the TITANUS TOP∙SENS® combines maximum sensitivity and maximum security against false alarms in rooms as large as 5,760m². A second detector module can be used to create a dual detector dependency setup, or to monitor a second area independently. Each detector module can be configured with up to three alarm levels. An additional connection socket makes parallel display possible.\u003c\/p\u003e\n\u003cp\u003eTITANUS TOP·SENS® is a modular ASD and consist of the basic device (1), one or two detector modules (2) and an adhesive front film sheet (3) which can be selected from the below combinations.\u003c\/p\u003e\n\u003cp\u003eThe TITANUS TOP·SENS® has all the features of the PRO·SENS®, plus a network card slot to allow network capability via Ethernet \/ SNMP connection. This premium product includes a bar graph to display smoke density levels in the event of fire.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMax. fire alarm sensitivity 0.015 % obsc.\/m\u003c\/li\u003e\n\u003cli\u003eSystem coverage up to 2 x 3,000m²\u003c\/li\u003e\n\u003cli\u003eUp to 2 x 300m pipe length and depending on version up to 2 x 72 holes\u003c\/li\u003e\n\u003cli\u003eOperating temperature: from -20°C up to 60°C and -40°C depending on version\u003c\/li\u003e\n\u003cli\u003eDisplay of info-alarm, pre-alarm and main alarm as well as bar graph display of smoke level\u003c\/li\u003e\n\u003cli\u003eFree slots for integration of additional modules such as bus modules\u003c\/li\u003e\n\u003cli\u003eOptional Ethernet\/SNMP\/data logger\u003c\/li\u003e\n\u003cli\u003eSound pressure level from 23 dB(A) for SILENT version\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Data:\u003c\/h2\u003e\n\u003ch3\u003eMechanical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions mm (W x H x D)\u003c\/strong\u003e\u003cbr\u003e200 x 292 x 113\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe length (max.)\u003c\/strong\u003e\u003cbr\u003e2 x 300m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of sampling points (max.)\u003c\/strong\u003e\u003cbr\u003e1 x 100; 2 x 63 (SL: 2 x 72**)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe inlets\u003c\/strong\u003e\u003cbr\u003e2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArea of coverage (max.)\u003c\/strong\u003e\u003cbr\u003e2 x 3.000m²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of alarm thresholds per detector module\u003c\/strong\u003e\u003cbr\u003e3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAmbient Conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions mm (W x H x D)\u003c\/strong\u003e\u003cbr\u003e200 x 292 x 113\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe length (max.)\u003c\/strong\u003e\u003cbr\u003e2 x 300 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of sampling points (max.)\u003c\/strong\u003e\u003cbr\u003e1 x 100; 2 x 63 (SL: 2 x 72**)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe inlets\u003c\/strong\u003e\u003cbr\u003e2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003cbr\u003e24 V DC (14 ... 30 V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiescent current, starting current (1 detector module) *\u003c\/strong\u003e\u003cbr\u003e200 mA, 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiescent current, starting current (2 detector modules) *\u003c\/strong\u003e\u003cbr\u003e230 mA, 330 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm current with and without reset circuit board (1 detector module)*\u003c\/strong\u003e\u003cbr\u003e20 mA, 230 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm current with rand without reset circuit board (2 detector modules)*\u003c\/strong\u003e\u003cbr\u003e20 mA, 290 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003cbr\u003eEN 54-20, EN 54-17\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* at 6.9 V standard fan voltage\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e** when using the fan board FC-3\u003c\/em\u003e\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57103937896793,"sku":"AD-10-1210","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/Image_placeholders__Fireclass.png?v=1768243377","url":"https:\/\/ifp-uk.com\/products\/fw-tt-2-front-film-tt-2-for-2-detectors-ad-10-1210","provider":"International Fire Protection","version":"1.0","type":"link"}