{"title":"FireClass","description":"","products":[{"product_id":"product-example-d","title":"FireClass FC440AVB - Addressable Base Sounder VAD Standard Power - 576.440.006","description":"\u003cp\u003eThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm\u003cbr\u003edevice specifically for use with the FireClass addressable detectors. The bases\u003cbr\u003eare available as fire alarm sounders with visual alarm device (VAD) in two power\u003cbr\u003eoutputs, Standard and High. The High power option provides more coverage for the\u003cbr\u003eVAD compared to Standard. Each has an address so they can be monitored and\u003cbr\u003econtrolled from the fire alarm control panel, which is independent of the detector fitted to the base.\u003c\/p\u003e\n\u003cp\u003eThe power and communications for the sounder, VAD and detector are\u003cbr\u003eprovided by the digital loop. This helps to reduce installation costs as no additional\u003cbr\u003ewiring is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- A compact and discrete solution\u003cbr\u003e- VAD approved to EN54-23 with two ranges, standard\u003cbr\u003epower and high power available\u003cbr\u003e- High Power option provides a larger VAD coverage\u003cbr\u003evolume compared to Standard\u003cbr\u003e- Reflective Sound Monitoring (RSM)\u003cbr\u003e- Reflective Light Monitoring (RLM)\u003cbr\u003e- Self-test (**)\u003cbr\u003e- Shorter Light Pulse for faster response\u003cbr\u003e- Optimise the system design for lowest power\u003cbr\u003erequirements and lowest cost installation\u003cbr\u003e- Triple light source\u003cbr\u003e- One point of installation for detector, sounder and visual indicator with no additional wiring\u003cbr\u003e- Independent addressable control of the sounder and beacon\u003cbr\u003e- Built-in line isolator\u003cbr\u003e- Select the tone, volume and flash rate using panel configuration software\u003cbr\u003e- 15 selectable tones. Allows users to select the tone with which they are most familiar.\u003cbr\u003e- Realistic Conventional Bell Tone\u003cbr\u003e- 2 selectable volumes\u003cbr\u003e- 2 selectable flash rates\u003cbr\u003e- Different tones can be used for fire alarm and class change\u003cbr\u003e- VADs and sounders are synchronised over the entire loop\u003cbr\u003e- A locking pin supplied with the base which prevents the unauthorized removal of the detector\u003cbr\u003e- Provides an EN54-23 approved upgrade path for legacy systems\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47572704330073,"sku":"576.440.006","price":89.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/TycoAddressableBaseSounderBeaconVAD1-941181.jpg?v=1716220787"},{"product_id":"product-example-e","title":"FireClass FC440AVR - Addressable Wall Sounder VAD Red - 576.440.008","description":"\u003cp\u003eThe FC440AV range of compact addressable wall sounders with a visual alarm\u003cbr\u003edevice (VAD) includes three models with the same low current and high output\u003cbr\u003especification; red and white body indoor models plus an IP rated version for either\u003cbr\u003eoutdoor or harsh environment applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- Compact and unobtrusive sounder solution\u003cbr\u003e- Reflective Sound Monitoring (RSM)\u003cbr\u003e- Reflective Light Monitoring (RLM)\u003cbr\u003e- Self-test (**)\u003cbr\u003e- Shorter Light Pulse for faster response\u003cbr\u003e- Indoor and outdoor versions\u003cbr\u003e- Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box\u003cbr\u003e- IP rated option has a deep surface back box for use with\u003cbr\u003esuitable IP-rated glands and cabling\u003cbr\u003e- Power and data from the loop.\u003cbr\u003e- Built-in line isolator\u003cbr\u003e- 16 selectable tones\u003cbr\u003e- Realistic Conventional Bell Tone\u003cbr\u003e- 2 selectable volumes\u003cbr\u003e- 2 selectable flash rates\u003cbr\u003e- Select the tone volume and flash rate using panel\u003cbr\u003econfiguration software\u003cbr\u003e- Independent addressable control of the sounder and beacon\u003cbr\u003e- Different tones can be used for fire alarm and class change\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47572704592217,"sku":"576.440.008","price":99.74,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FC440AVR-551014.jpg?v=1716220787"},{"product_id":"product-example-f","title":"FireClass FC440AVW - Addressable Wall Sounder VAD White - 576.440.007","description":"\u003cp\u003eThe FC440AV range of compact addressable wall sounders with a visual alarm\u003cbr data-mce-fragment=\"1\"\u003edevice (VAD) includes three models with the same low current and high output\u003cbr data-mce-fragment=\"1\"\u003especification; red and white body indoor models plus an IP rated version for either\u003cbr data-mce-fragment=\"1\"\u003eoutdoor or harsh environment applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- Compact and unobtrusive sounder solution\u003cbr\u003e- Reflective Sound Monitoring (RSM)\u003cbr\u003e- Reflective Light Monitoring (RLM)\u003cbr\u003e- Self-test (**)\u003cbr\u003e- Shorter Light Pulse for faster response\u003cbr\u003e- Indoor and outdoor versions\u003cbr\u003e- Indoor models can be semi-flush or surface mounted\u003cbr\u003eincluding a choice of shallow or deep back box\u003cbr\u003e- IP rated option has a deep surface back box for use with\u003cbr\u003esuitable IP-rated glands and cabling\u003cbr\u003e- Power and data from the loop.\u003cbr\u003e- Built-in line isolator\u003cbr\u003e- 16 selectable tones\u003cbr\u003e- Realistic Conventional Bell Tone\u003cbr\u003e- 2 selectable volumes\u003cbr\u003e- 2 selectable flash rates\u003cbr\u003e- Select the tone volume and flash rate using panel configuration software\u003cbr\u003e- Independent addressable control of the sounder and beacon\u003cbr\u003e- Different tones can be used for fire alarm and class change\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47572705050969,"sku":"576.440.007","price":99.74,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FC440AVW-954588.jpg?v=1716220786"},{"product_id":"fc460ph-combined-optical-and-heat-detector","title":"FireClass FC460PH - Combined Optical and Heat Detector - 516.460.501","description":"\u003cp data-mce-fragment=\"1\"\u003eThe FC460 range of detectors use the FireClass digital protocol to provide robust and reliable communications to the control panel. A wide range of cable types can be used and the open topology capability of the system makes it ideal for the upgrade of older systems whilst reusing the cables to reduce cost.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFireClass FC460 detectors provide the best in class environmental and detection performance with the capability of detecting all fire types. The Range includes an Optical\/Heat Multisensor and Optical\/Heat\/CO Triple Multisensor.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAutomatic self testing of each sensor element offers reassurance of operation at all times and the 360º alarm, isolated and fault LED on each detector provides instant line of sight. Fourteen EN54 approved modes\/sensitivities for the Optical\/ Heat Multisensor help to provide one of the best and most versatile detectors on the market.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation Features \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStandard bases with multiple mounting options simplify installation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnique ‘park’ position for commissioning and service procedures\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetector addressing programmed from the Service tool or FireClass control panels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAddress flag—fixed to the base to prevent mix ups during service\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFull range of remote installation and service tools\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDirty detector read-out can be viewed on the service tool or panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFC460PH\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith its ability to detect a wide range of fires, from flaming to smoldering types, the combined optical and heat multi-sensor detector is the preferred choice for a range of applications including light industrial, retail and office environments.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIt operates in a number of approved modes and sensitivities that can be dynamically selected to suit different environmental conditions.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47601860051289,"sku":"516.460.501","price":33.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FireClassMultiSensorSmokeDetectorAddressableHeatCarbonMonoxide_CO_AlarmFC460PC516.460.504_6d5f7eaf-32fb-4a10-a2e4-c88b41e794d9-453006.jpg?v=1716220852"},{"product_id":"fc460h-optical-detector-516-460-502","title":"FireClass FC460P - Optical Detector - 516.460.502","description":"\u003cp data-mce-fragment=\"1\"\u003eThe FC460 range of detectors use the FireClass digital protocol to provide robust and reliable communications to the control panel. A wide range of cable types can be used and the open topology capability of the system makes it ideal for the upgrade of older systems whilst reusing the cables to reduce cost.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFireClass FC460 detectors provide the best in class environmental and detection performance with the capability of detecting all fire types. The Range includes an Optical\/Heat Multisensor and Optical\/Heat\/CO Triple Multisensor.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAutomatic self testing of each sensor element offers reassurance of operation at all times and the 360º alarm, isolated and fault LED on each detector provides instant line of sight. Fourteen EN54 approved modes\/sensitivities for the Optical\/ Heat Multisensor help to provide one of the best and most versatile detectors on the market.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation Features \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStandard bases with multiple mounting options simplify installation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnique ‘park’ position for commissioning and service procedures\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetector addressing programmed from the Service tool or FireClass control panels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAddress flag—fixed to the base to prevent mix ups during service\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFull range of remote installation and service tools\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDirty detector read-out can be viewed on the service tool or panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFC460P \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMore benign environments where any potential fire will be slow burning can be protected using the optical detector. A choice of sensitivities gives this detector a broad range of applications.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47602043421017,"sku":"516.460.502","price":30.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FireClassMultiSensorSmokeDetectorAddressableHeatCarbonMonoxide_CO_AlarmFC460PC516.460.504_5bea2c56-a06b-4fd4-872b-82d215a0460c-237775.jpg?v=1716220786"},{"product_id":"fc460h-heat-detector-516-460-503","title":"FireClass FC460H - Heat Detector - 516.460.503","description":"\u003cp data-mce-fragment=\"1\"\u003eThe FC460 range of detectors use the FireClass digital protocol to provide robust and reliable communications to the control panel. A wide range of cable types can be used and the open topology capability of the system makes it ideal for the upgrade of older systems whilst reusing the cables to reduce cost.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFireClass FC460 detectors provide the best in class environmental and detection performance with the capability of detecting all fire types. The Range includes an Optical\/Heat Multisensor and Optical\/Heat\/CO Triple Multisensor.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAutomatic self testing of each sensor element offers reassurance of operation at all times and the 360º alarm, isolated and fault LED on each detector provides instant line of sight. Fourteen EN54 approved modes\/sensitivities for the Optical\/ Heat Multisensor help to provide one of the best and most versatile detectors on the market.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation Features \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStandard bases with multiple mounting options simplify installation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnique ‘park’ position for commissioning and service procedures\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetector addressing programmed from the Service tool or FireClass control panels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAddress flag—fixed to the base to prevent mix ups during service\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFull range of remote installation and service tools\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDirty detector read-out can be viewed on the service tool or panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFC460H\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eComplimenting the range is the heat sensor which can operate in fixed temperature and rate-of-rise modes. It is most often used in areas where high levels of dust are present or where the environment precludes the use of smoke detectors.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47602081431897,"sku":"516.460.503","price":30.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FireClassMultiSensorSmokeDetectorAddressableHeatCarbonMonoxide_CO_AlarmFC460PC516.460.504_98a08305-f6f2-4522-8897-97255385a682-681871.jpg?v=1716220787"},{"product_id":"fc460pc-smoke-heat-and-carbon-monoxide-detector-516-460-504","title":"FireClass FC460PC - Smoke, Heat and Carbon Monoxide Detector - 516.460.504","description":"\u003cp data-mce-fragment=\"1\"\u003eThe FC460 range of detectors use the FireClass digital protocol to provide robust and reliable communications to the control panel. A wide range of cable types can be used and the open topology capability of the system makes it ideal for the upgrade of older systems whilst reusing the cables to reduce cost.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFireClass FC460 detectors provide the best in class environmental and detection performance with the capability of detecting all fire types. The Range includes an Optical\/Heat Multisensor and Optical\/Heat\/CO Triple Multisensor.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAutomatic self testing of each sensor element offers reassurance of operation at all times and the 360º alarm, isolated and fault LED on each detector provides instant line of sight. Fourteen EN54 approved modes\/sensitivities for the Optical\/ Heat Multisensor help to provide one of the best and most versatile detectors on the market.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation Features \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStandard bases with multiple mounting options simplify installation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnique ‘park’ position for commissioning and service procedures\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetector addressing programmed from the Service tool or FireClass control panels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAddress flag—fixed to the base to prevent mix ups during service\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFull range of remote installation and service tools\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDirty detector read-out can be viewed on the service tool or panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFC460PC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFor life protection and when the environmental conditions are challenging, the multisensor smoke, heat and CO detector provides the ultimate in detector performance. It uses the three sensor elements in concert to accurately determine the presence of fire with false alarm rejection properties that make it the ideal choice for hotel bedrooms where steam from bathrooms is a common source of false alarms.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47602086969689,"sku":"516.460.504","price":51.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FireClassMultiSensorSmokeDetectorAddressableHeatCarbonMonoxide_CO_AlarmFC460PC516.460.504_fb546f93-da12-408a-8f07-c6d01d9aaf24-243937.jpg?v=1716220852"},{"product_id":"fc420cp-i-indoor-callpoint-514-800-805","title":"FireClass FC420CP-I  - Indoor Callpoint - 514.800.805","description":"\u003cp\u003eA comprehensive range of call points for use with FireClass addressable systems, using the robust and reliable FireClass open protocol. All the callpoints are designed to enable an alarm signal to be given by a plastic resettable element, which means that the call point can be easily reset after it has been activated.\u003c\/p\u003e\n\u003cp\u003eAny change in the status of the switch is immediately communicated to the FireClass Control and Indicating Equipment (CIE). All call points have an integral short-circuit isolator for monitoring the addressable loop wiring. The integral LED indicator is normally off.\u003c\/p\u003e\n\u003cp\u003eWhen the frangible element is broken, an alarm is registered and the LED will illuminate red. If a section of the loop wiring adjacent to the call point is shorted, the built-in short-circuit isolator trips, isolating the shorted section and the LED is illuminated yellow.\u003c\/p\u003e\n\u003cp\u003eThe status remains until the short is removed. If required, an optional transparent hinged cover may be installed to guard against accidental operation. Both indoor and outdoor versions are available\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Integral Short Circuit Isolator\u003c\/p\u003e\n\u003cp\u003e• Dual Colour LED Indication\u003c\/p\u003e\n\u003cp\u003e• EN54-11 Certification\u003c\/p\u003e\n\u003cp\u003e• Compact, Modern Styling\u003c\/p\u003e\n\u003cp\u003e• Test Key for Fast Testing\u003c\/p\u003e\n\u003cp\u003e• IP67 Ingress Protection models for external applications\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47602128748889,"sku":"514.800.805","price":29.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/ManualCallPoint_b2f7ccd3-f705-42f9-8573-2a6543cbd6ec-847196.jpg?v=1716220786"},{"product_id":"4b-detector-base-517-050-041","title":"FireClass 4B Detector Base - 517.050.041","description":"The Fireclass 4B is a detector base for use with the Fireclass FC460 range of addressable detectors.","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47602200412505,"sku":"517.050.041","price":2.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/4bBase-751496.jpg?v=1713277251"},{"product_id":"fireclass-fc602-2-loop-addressable-fire-alarm-control-panel-557-200-650","title":"FireClass FC602 - 2 Loop Addressable Fire Alarm Control Panel - 557.200.650","description":"\u003cp\u003eThe FC602S is a compact two-loop FireClass networkable panel with a shallow\u003cbr data-mce-fragment=\"1\"\u003ehousing. It can have two standard-power loops or one high-power loop with each\u003cbr data-mce-fragment=\"1\"\u003epanel having a maximum of 250 addresses. The panel features a colour LCD display\u003cbr data-mce-fragment=\"1\"\u003ewith 32 zonal LEDs, and has a maximum capacity of 17Ah batteries.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC602S panel is also available as a Scandinavian variant with fireman’s\u003cbr data-mce-fragment=\"1\"\u003ekeyswitch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- 250 addresses available on panel.\u003cbr\u003e- Colour LCD display with 32 zonal LEDs\u003cbr\u003e- Simple to operate user interface\u003cbr\u003e- Flexible loop configurations with up to 1A current to increase use of loop power\u003cbr\u003eand address capacity\u003cbr\u003e- Comprehensive point management\u003cbr\u003e- 10000 event log\u003cbr\u003e- Editable quiescent display text\u003cbr\u003e- Extensive special cause and effect programming\u003cbr\u003e- Manual and automatic walk test\u003cbr\u003e- Automatic battery test\u003cbr\u003e- Detector service functions\u003cbr\u003e- Front panel controls enabling text and configuration changes\u003cbr\u003e- Networkable\u003cbr\u003e- Up to seven fully functional repeaters\u003cbr\u003e- Optional easy-mount plate\u003cbr\u003e- Optional expansion kit for mounting additional cards\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802654916953,"sku":"557.200.650","price":737.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/602_4-319231.jpg?v=1716220852"},{"product_id":"fc604s-4-loop-addressable-fire-alarm-control-panel-557-200-651","title":"FireClass FC604S - 4 Loop Addressable Fire Alarm Control Panel - 557.200.651","description":"\u003cp\u003eThe FC604S is a four loop FireClass networkable panel with a shallow housing. This\u003cbr data-mce-fragment=\"1\"\u003epanel can have four standard-power loops or two high-power loops with each panel\u003cbr data-mce-fragment=\"1\"\u003ehaving a maximum of 500 addresses. It features a colour LCD display with 32 zonal\u003cbr data-mce-fragment=\"1\"\u003eLEDs, and has a maximum capacity of 17 Ah batteries.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC604S panel is also available as a Scandinavian variant with fireman’s\u003cbr data-mce-fragment=\"1\"\u003ekeyswitch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Colour LCD display with 32 zonal LEDs\u003cbr data-mce-fragment=\"1\"\u003e- Simple to operate user interface\u003cbr data-mce-fragment=\"1\"\u003e- Flexible loop configurations with up to 1A current to increase use of loop power and address capacity\u003cbr data-mce-fragment=\"1\"\u003e- Comprehensive point management\u003cbr data-mce-fragment=\"1\"\u003e- 10000 event log\u003cbr data-mce-fragment=\"1\"\u003e- Editable quiescent display text\u003cbr data-mce-fragment=\"1\"\u003e- Extensive special cause and effect programming\u003cbr data-mce-fragment=\"1\"\u003e- Manual and automatic walk test\u003cbr data-mce-fragment=\"1\"\u003e- Automatic battery test\u003cbr data-mce-fragment=\"1\"\u003e- Detector service functions\u003cbr data-mce-fragment=\"1\"\u003e- Front panel controls enabling text and configuration changes\u003cbr data-mce-fragment=\"1\"\u003e- Networkable\u003cbr data-mce-fragment=\"1\"\u003e- Up to seven fully functional repeaters\u003cbr data-mce-fragment=\"1\"\u003e- Optional easy-mount plate\u003cbr data-mce-fragment=\"1\"\u003e- Optional expansion kit for mounting additional cards\u003cbr\u003e\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802742112601,"sku":"557.200.651","price":945.47,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/602_4_47622eeb-e295-4c8b-885f-b69c46ea05e6-301043.jpg?v=1716220853"},{"product_id":"fireclass-fc32ar-32-zone-ac-repeater-557-200-654","title":"FireClass FC32AR - 32 Zone AC Repeater - 557.200.654","description":"\u003cp\u003eThe FC600 range of repeaters include both AC and DC powered models, featuring a\u003cbr data-mce-fragment=\"1\"\u003ecolour LCD display with 32 LED zonal display.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eBoth repeaters are also available as a Scandinavian variant with fireman’s keyswitch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- Colour LCD display with 32 zonal LEDs\u003cbr\u003e- Simple to operate user interface\u003cbr\u003e- Editable quiescent display text\u003cbr\u003e- Front panel controls enabling text and configuration changes\u003cbr\u003e- Up to seven fully functional repeaters\u003cbr\u003e- Optional easy-mount plate (for AC repeater)\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802761281881,"sku":"557.200.654","price":680.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/557.200.650FC602SPanelFront-880346.jpg?v=1713277430"},{"product_id":"fireclass-fc32dr-32-zone-dc-repeater-557-200-655","title":"FireClass FC32DR - 32 Zone DC Repeater - 557.200.655","description":"\u003cp\u003eThe FC600 range of repeaters include both AC and DC powered models, featuring a\u003cbr data-mce-fragment=\"1\"\u003ecolour LCD display with 32 LED zonal display.\u003c\/p\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003eBoth repeaters are also available as a Scandinavian variant with fireman’s keyswitch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Colour LCD display with 32 zonal LEDs\u003cbr\u003e- Simple to operate user interface\u003cbr\u003e- Editable quiescent display text\u003cbr\u003e- Front panel controls enabling text and configuration changes\u003cbr\u003e- Up to seven fully functional repeaters\u003cbr\u003e- Optional easy-mount plate (for AC repeater)\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802764558681,"sku":"557.200.655","price":605.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FC32DR32zoneDCRepeaterScandinavian-939109.jpg?v=1713277430"},{"product_id":"fireclass-fc702-addressable-fire-alarm-panel-557-200-949","title":"FireClass FC702 - Addressable Fire Alarm Panel - 557.200.949","description":"\u003cp\u003eThe two loop addressable panel from FireClass is a highly featured digital\u003cbr data-mce-fragment=\"1\"\u003eaddressable fire alarm system with an advanced TFT colour touch-screen user\u003cbr data-mce-fragment=\"1\"\u003einterface that is ergonomically engineered specifically for fire alarm control.\u003cbr data-mce-fragment=\"1\"\u003eOperation of the touch screen is possible with or without gloves and provides easy to-\u003cbr data-mce-fragment=\"1\"\u003euse, intuitive user controls including keyless log-on using RFID cards.\u003c\/p\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe FC702S is housed in a compact shallow enclosure whilst the FC702D has a\u003cbr data-mce-fragment=\"1\"\u003edeep housing to accommodate larger batteries for extended standby periods. Each\u003cbr data-mce-fragment=\"1\"\u003epanel can support 250 addresses in total and panels can be seamlessly networked\u003cbr data-mce-fragment=\"1\"\u003etogether making it suitable for a range of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- 8.4” TFT colour touch screen multilingual user interface\u003cbr\u003e- Ergonomic Icon Displa\u003cbr\u003e- Touch sensitive status LEDs provide event summary information\u003cbr\u003e- Context sensitive help and on screen operator instructions\u003cbr\u003e- User configurable on screen site maps\u003cbr\u003e- Programmable graphic quiescent display\u003cbr\u003e- Comprehensive point management and disable functions\u003cbr\u003e- Selectively view or print from the extensive 10,000 event log using dynamic filters\u003cbr\u003e- Keyless log-on using RFID tags\u003cbr\u003e- Flexible single or dual hardware loop configurations\u003cbr\u003e- Compact shallow housing or deep housing\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802781532505,"sku":"557.200.949","price":1018.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/NEWFC702S_Panel_Front_92e51ecd-0d2e-408a-be56-3ed4f5ecaa5b-553488.jpg?v=1716220852"},{"product_id":"fireclass-4b-i-isolator-base-517-050-043","title":"FireClass 4B-I Isolator Base - 517.050.043","description":"\u003cp\u003eThe 4B-I 4” Isolator base is designed to snap-fit to the ceiling tile adaptor or it\u003cbr data-mce-fragment=\"1\"\u003ecan screw fix to a ceiling in the traditional manner. The 4B-I 4” base is designed\u003cbr data-mce-fragment=\"1\"\u003especifically for use with the FC460 series detectors and provides protection against\u003cbr data-mce-fragment=\"1\"\u003eshort circuit faults on the digital addressable loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e• Drives a remote indicator.\u003cbr\u003e• Detector locking pin provided with every base.\u003cbr\u003e• Snap fits to the Time SaverCeiling Tile Adaptor.\u003cbr\u003e• Temporary park position\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802946388313,"sku":"517.050.043","price":7.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/4bBase_f7f54523-27f8-41ce-b58f-08f3bf1b9582-781577.jpg?v=1713277429"},{"product_id":"copy-of-fireclass-fc440avr-addressable-wall-sounder-vad-red-576-440-008","title":"FireClass FC445AVR  - Addressable Wall Sounder VAD IP Red - 576.440.009","description":"\u003cp\u003eThe FC440AV range of compact addressable wall sounders with a visual alarm\u003cbr\u003edevice (VAD) includes three models with the same low current and high output\u003cbr\u003especification; red and white body indoor models plus an IP rated version for either\u003cbr\u003eoutdoor or harsh environment applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- Compact and unobtrusive sounder solution\u003cbr\u003e- Reflective Sound Monitoring (RSM)\u003cbr\u003e- Reflective Light Monitoring (RLM)\u003cbr\u003e- Self-test (**)\u003cbr\u003e- Shorter Light Pulse for faster response\u003cbr\u003e- Indoor and outdoor versions\u003cbr\u003e- Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box\u003cbr\u003e- IP rated option has a deep surface back box for use with\u003cbr\u003esuitable IP-rated glands and cabling\u003cbr\u003e- Power and data from the loop.\u003cbr\u003e- Built-in line isolator\u003cbr\u003e- 16 selectable tones\u003cbr\u003e- Realistic Conventional Bell Tone\u003cbr\u003e- 2 selectable volumes\u003cbr\u003e- 2 selectable flash rates\u003cbr\u003e- Select the tone volume and flash rate using panel \u003cbr\u003econfiguration software\u003cbr\u003e- Independent addressable control of the sounder and beacon\u003cbr\u003e- Different tones can be used for fire alarm and class change\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47802966737241,"sku":"576.440.009","price":112.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/vidsangle-913845.jpg?v=1716220786"},{"product_id":"copy-of-fireclass-fc440avb-addressable-base-sounder-vad-standard-power-576-440-006","title":"FireClass FC441AVB - Addressable Base Sounder VAD Standard Power - 576.440.014","description":"\u003cp\u003eThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm\u003cbr\u003edevice specifically for use with the FireClass addressable detectors. The bases\u003cbr\u003eare available as fire alarm sounders with visual alarm device (VAD) in two power\u003cbr\u003eoutputs, Standard and High. The High power option provides more coverage for the\u003cbr\u003eVAD compared to Standard. Each has an address so they can be monitored and\u003cbr\u003econtrolled from the fire alarm control panel, which is independent of the detector fitted to the base.\u003c\/p\u003e\n\u003cp\u003eThe power and communications for the sounder, VAD and detector are\u003cbr\u003eprovided by the digital loop. This helps to reduce installation costs as no additional\u003cbr\u003ewiring is required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- A compact and discrete solution\u003cbr\u003e- VAD approved to EN54-23 with two ranges, standard\u003cbr\u003epower and high power available\u003cbr\u003e- High Power option provides a larger VAD coverage\u003cbr\u003evolume compared to Standard\u003cbr\u003e- Reflective Sound Monitoring (RSM)\u003cbr\u003e- Reflective Light Monitoring (RLM)\u003cbr\u003e- Self-test (**)\u003cbr\u003e- Shorter Light Pulse for faster response\u003cbr\u003e- Optimise the system design for lowest power\u003cbr\u003erequirements and lowest cost installation\u003cbr\u003e- Triple light source\u003cbr\u003e- One point of installation for detector, sounder and visual indicator with no additional wiring\u003cbr\u003e- Independent addressable control of the sounder and beacon\u003cbr\u003e- Built-in line isolator\u003cbr\u003e- Select the tone, volume and flash rate using panel configuration software\u003cbr\u003e- 15 selectable tones. Allows users to select the tone with which they are most familiar.\u003cbr\u003e- Realistic Conventional Bell Tone\u003cbr\u003e- 2 selectable volumes\u003cbr\u003e- 2 selectable flash rates\u003cbr\u003e- Different tones can be used for fire alarm and class change\u003cbr\u003e- VADs and sounders are synchronised over the entire loop\u003cbr\u003e- A locking pin supplied with the base which prevents the unauthorized removal of the detector\u003cbr\u003e- Provides an EN54-23 approved upgrade path for legacy systems\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803011039577,"sku":"576.440.014","price":113.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/TycoAddressableBaseSounderBeaconVAD1_7f1e2e75-c8d7-41be-8ae9-58389027aefc-843087.jpg?v=1716220787"},{"product_id":"fireclass-fc410dim-detector-input-module-555-800-712","title":"FireClass FC410DIM - Detector Input Module - 555.800.712","description":"\u003cp\u003eThe Addressable FC410DIM provides the ability to connect and Interface one zone\u003cbr data-mce-fragment=\"1\"\u003eof conventional detectors (non-addressable) to the Fire Alarm Controller.\u003cbr data-mce-fragment=\"1\"\u003eThe FC410DIM monitors the status of detectors and wiring to detectors and\u003cbr data-mce-fragment=\"1\"\u003esignals detector and wiring status back to the Controller.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC410DIM requires a 24Vdc power supply.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803166163289,"sku":"555.800.712","price":67.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FC410DIMDETECTION-3-192341.jpg?v=1713277429"},{"product_id":"fireclass-fc410rim-relay-interface-module-568-800-703","title":"FireClass FC410RIM - Relay Interface Module - 568.800.703","description":"\u003cp\u003eThe FC410RIM Relay Interface Module provides one volt-free relay changeover\u003cbr data-mce-fragment=\"1\"\u003econtact on a latching relay. The relay is controlled by a command sent from the\u003cbr data-mce-fragment=\"1\"\u003eFireClass fire controller via the addressable loop.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe relay state (activated, deactivated or stuck) is returned to the\u003cbr data-mce-fragment=\"1\"\u003econtroller as confirmation\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803174781273,"sku":"568.800.703","price":27.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/RIM-671129.jpg?v=1713277505"},{"product_id":"fireclass-fc410bdm-beam-detector-interface-module-555-800-766","title":"FireClass FC410BDM - Beam Detector Interface Module - 555.800.766","description":"\u003cp\u003eThe FC410BDM Beam Detector Interface Module is designed to power and\u003cbr data-mce-fragment=\"1\"\u003einterface one FIRERAY 50\/100\/3000\/5000 Beam Detector to the FireClass Digital\u003cbr data-mce-fragment=\"1\"\u003eAddressable Loop.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC410BDM monitors the Fire and Fault contacts and also monitors for open\u003cbr data-mce-fragment=\"1\"\u003eand short circuits on the connections between the interface and the beam detector.\u003cbr data-mce-fragment=\"1\"\u003eFor remote siting of the FIRERAY detector an optional BTM800 Terminal Module\u003cbr data-mce-fragment=\"1\"\u003ecan be used.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803176190297,"sku":"555.800.766","price":93.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/555.800.766-478501.jpg?v=1713277429"},{"product_id":"fireclass-fc410snm-sounder-notification-module-577-800-705","title":"FireClass FC410SNM - Sounder Notification Module - 577.800.705","description":"\u003cp\u003eThe FC410SNM Sounder Notification Module is designed to provide an output,\u003cbr data-mce-fragment=\"1\"\u003ein response to a command signaled from a controller, to activate a number\u003cbr data-mce-fragment=\"1\"\u003eof polarized and suppressed sounders.\u003c\/p\u003e\n\u003cp\u003eThe sounders are powered from an\u003cbr data-mce-fragment=\"1\"\u003eindependent power supply and the module is capable of passing up to a maximum\u003cbr data-mce-fragment=\"1\"\u003eof 2A (e.g., 24V dc 50mA company sounders or a mixture of different current rated\u003cbr data-mce-fragment=\"1\"\u003esounders not exceeding a maximum current of 2A).\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803180679513,"sku":"577.800.705","price":62.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FC410SNM-754759.jpg?v=1713277505"},{"product_id":"fireclass-btm800-beam-detector-module-555-800-067","title":"FireClass  BTM800 - Beam Detector Module - 555.800.067","description":"\u003cp\u003eIn many cases it will be necessary to site the FC410BDM Beam Detector Module\u003cbr data-mce-fragment=\"1\"\u003esome distance from the beam detector itself. To minimize and simplify wiring in\u003cbr data-mce-fragment=\"1\"\u003esuch cases an optional unit, the BTM800 beam termination module is available.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe BTM800 is also housed in a standard double gang ancillary cover and has all\u003cbr data-mce-fragment=\"1\"\u003ethe connections and components required to minimize installation time.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803182645593,"sku":"555.800.067","price":62.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/BTM800-720007.jpg?v=1713277250"},{"product_id":"fireclass-hvr800-high-voltage-relay-interface-568-800-004","title":"FireClass  HVR800 - High Voltage Relay Interface - 568.800.004","description":"\u003cp\u003eThe HVR800 High Voltage Relay Interface is a non-addressable multi-voltage\u003cbr data-mce-fragment=\"1\"\u003erelay module (operating from 24V DC, 24V AC, 120V AC and 240V AC).\u003cbr data-mce-fragment=\"1\"\u003eThe encapsulated HVR800 provides a 10 amp volt-free contact that can be used to\u003cbr data-mce-fragment=\"1\"\u003eextend the contact ratings of FC410RIM Addressable Relay Module applications.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eA maximum of four HVR800s can be individually driven and controlled by an\u003cbr data-mce-fragment=\"1\"\u003eFC410MIO Small Addressable Multi-Input\/Output module if all HVR800s are\u003cbr data-mce-fragment=\"1\"\u003epowered by 120V AC or 240V AC. For ac operation, no external DC power supply\u003cbr data-mce-fragment=\"1\"\u003eunit is required to operate the relay. When used to switch 24V DC, the HVR800\u003cbr data-mce-fragment=\"1\"\u003emust be provided with an external 24V DC supply which should be switched\u003cbr data-mce-fragment=\"1\"\u003ethrough the clean relay contacts of an FC410MIO or FC410RIM.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803188379993,"sku":"568.800.004","price":41.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/2_d0a50fbb-7652-4828-84a7-a15a56c03e0d-892707.png?v=1716220437"},{"product_id":"copy-of-fireclass-hvr800-high-voltage-relay-interface-568-800-004","title":"FireClass  HVR800 - High Voltage Relay Interface in D800 Housing - 568.800.034","description":"\u003cp\u003eThe HVR800 High Voltage Relay Interface is a non-addressable multi-voltage\u003cbr data-mce-fragment=\"1\"\u003erelay module (operating from 24V DC, 24V AC, 120V AC and 240V AC).\u003cbr data-mce-fragment=\"1\"\u003eThe encapsulated HVR800 provides a 10 amp volt-free contact that can be used to\u003cbr data-mce-fragment=\"1\"\u003eextend the contact ratings of FC410RIM Addressable Relay Module applications.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eA maximum of four HVR800s can be individually driven and controlled by an\u003cbr data-mce-fragment=\"1\"\u003eFC410MIO Small Addressable Multi-Input\/Output module if all HVR800s are\u003cbr data-mce-fragment=\"1\"\u003epowered by 120V AC or 240V AC. For ac operation, no external DC power supply\u003cbr data-mce-fragment=\"1\"\u003eunit is required to operate the relay. When used to switch 24V DC, the HVR800\u003cbr data-mce-fragment=\"1\"\u003emust be provided with an external 24V DC supply which should be switched\u003cbr data-mce-fragment=\"1\"\u003ethrough the clean relay contacts of an FC410MIO or FC410RIM.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803188543833,"sku":"568.800.034","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FCD800-272474.jpg?v=1713277251"},{"product_id":"fireclass-fc410sio-single-input-output-module-555-800-763","title":"FireClass FC410SIO - Single Input\/Output Module - 555.800.763","description":"\u003cp\u003eThe FC410SIO Single Input\/Output Module is designed to provide a monitored\u003cbr data-mce-fragment=\"1\"\u003eopen collector input and a volt free relay changeover output.\u003c\/p\u003e\n\u003cp\u003eFC410SIO can switch up to 2 A @ 24 VDC.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803197948249,"sku":"555.800.763","price":50.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FC410SIO-755628.jpg?v=1713277505"},{"product_id":"fireclass-fc410qrm-quad-relay-module-555-800-773","title":"FireClass FC410QRM - Quad Relay Module - 555.800.773","description":"\u003cp\u003eThe FC410QRM Quad Relay Module is designed to provide four potential free relay\u003cbr data-mce-fragment=\"1\"\u003echangeover outputs. The outputs are monitored with parallel contacts of the relays.\u003cbr data-mce-fragment=\"1\"\u003eThe outputs can be connected to an Auxiliary Voltage source and its voltage can be\u003cbr data-mce-fragment=\"1\"\u003emonitored. The FC410QRM has an integral FireClass loop isolator. When a section\u003cbr data-mce-fragment=\"1\"\u003eof the loop adjacent is shorted, the isolator trips, isolating the shorted section, and\u003cbr data-mce-fragment=\"1\"\u003eilluminating a yellow LED. This status remains until the short is removed.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC410QRM must be fitted in a control enclosure or any distributor enclosure.\u003cbr data-mce-fragment=\"1\"\u003eThe FC410QRM will preferably be mounted via a DIN rail. Alternatively, it can\u003cbr data-mce-fragment=\"1\"\u003ebe directly fixed on the rear side of the enclosure. Furthermore, all outputs are\u003cbr data-mce-fragment=\"1\"\u003econfigurable to the HVR - mode (High Voltage Relay), which allows connection of\u003cbr data-mce-fragment=\"1\"\u003eup to four HVR800 modules for switching e.g. 240V loads galvanic isolated.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803206402393,"sku":"555.800.773","price":108.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/QRM-828384.jpg?v=1713277505"},{"product_id":"fireclass-fc410tsm-door-control-module-555-800-769","title":"FireClass FC410TSM - Door Control Module - 555.800.769","description":"\u003cp\u003eWhen activated, either by a fire signal or by a fault or isolation within the fire door\u003cbr data-mce-fragment=\"1\"\u003ezone, the FC410TSM will interrupt the supply to the door holders and the doors\u003cbr data-mce-fragment=\"1\"\u003eunder control of the module will close.\u003c\/p\u003e\n\u003cp\u003eThe module has the provision to monitor a contact to report to the fire controller if the door fails to close. The module also includes a built-in line isolator.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803208597849,"sku":"555.800.769","price":132.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/TSM-857184.jpg?v=1713277505"},{"product_id":"fireclass-fc470mdgb-b-metal-d-gang-b-box-517-035-011","title":"FireClass FC470MDGB - B Metal D\/Gang B\/Box - 517.035.011","description":"FC470MDGB Metal surface mount MK backbox for use with FC410 Series\u003cbr data-mce-fragment=\"1\"\u003eaddressable ancillaries using 517.035.007 cover.","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803210170713,"sku":"517.035.011","price":11.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/ModMKBackBox-994086.jpg?v=1716220852"},{"product_id":"fireclass-din-rail-mounting-bracket-547-004-002","title":"FireClass - DIN Rail Mounting Bracket - 547.004.002","description":"\u003cp\u003eDIN rail mounting bracket enables any module which can be mounted to a FC470CV ancillary cover to be DIN rail mounted using this bracket.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eClip-on PCB mounting pillars are included. Will fit standard 35 mm DIN Rail bracket. \u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47803215348057,"sku":"","price":19.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/547004002-981090.jpg?v=1713277251"},{"product_id":"copy-of-fireclass-702h-conventional-heat-detector-fixed-60-c-516-900-004","title":"FireClass 702CH - Conventional Multi Sensor CO and Heat Detector - 516.900.004","description":"\u003cp\u003e601CH detector is a unique general purpose fire detector which provides very early\u003cbr\u003ewarning of slow smouldering fires. Ideal for sleeping risks the CO fire detector is\u003cbr\u003ealso well suited to many applications where heat detection is insufficient but smoke\u003cbr\u003edetection causes false alarms.\u003cbr\u003eAs CO travels more freely than smoke the position of CO fire detectors is more\u003cbr\u003eflexible.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThis feature is particularly useful in large complex structures such as atria and warehouses, where the positioning of smoke detectors is difficult.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806034280793,"sku":"516.900.004","price":7.38,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/FireClassMultiSensorSmokeDetectorAddressableHeatCarbonMonoxide_CO_AlarmFC460PC516.460.504_cd541a02-08d4-442d-953d-c4d9555a3683-673125.jpg?v=1713277430"},{"product_id":"copy-of-fireclass-601f-conventional-solar-blind-infra-red-flame-detector-516-600-006","title":"FireClass 4B-DHM- Deck Head Mounting - 517.050.051","description":"\u003cp\u003eWhere the detectors are mounted in humid and environmentally challenging\u003cbr\u003esituations such as marine or offshore installations, the 4B DHM deck head mount\u003cbr\u003eprovides a sealed waterproof mounting which protects the electrical connections\u003cbr\u003ein the base. Can be screwed, bolted \/ welded to the deck head. Supplied with 1\u003cbr\u003eterminal. If more are required, use the optional base accessory.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eGeneral Features\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e• 4 x 20mm gland entries.\u003cbr\u003e• Fits ALL 5” bases.\u003cbr\u003e• IP55 with supplied gasket.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806045520217,"sku":"517.050.051","price":4.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/4b-dhm-833050.jpg?v=1713277430"},{"product_id":"copy-of-fireclass-4b-dhm-deck-head-mounting-517-050-051","title":"FireClass - Deck Head Mounting Terminal Kit - 517.050.612","description":"Optional terminal kit for FireClass 4B-DHM -Deck Head Mounting Base - 517.050.051","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806060298585,"sku":"517.050.612","price":2.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/2_d0a50fbb-7652-4828-84a7-a15a56c03e0d-225917.png?v=1716220438"},{"product_id":"square-remote-indicator-2500226","title":"Square Remote Indicator - 2500226","description":"\u003cp\u003eDesigned for fire detection systems requiring local indication of an individual\u003cbr data-mce-fragment=\"1\"\u003eor group of fire detectors in alarm mode, the VRLU indicator utilizes an\u003cbr data-mce-fragment=\"1\"\u003eultra-bright LED with a wide range of illumination.\u003c\/p\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe VRLU remote indicator is able to operate with many types of conventional\u003cbr data-mce-fragment=\"1\"\u003eand analogue addressable fire detectors, frequently eliminating the requirement\u003cbr data-mce-fragment=\"1\"\u003eto stock two types of indicator. The VRLU may also be used for other applications\u003cbr data-mce-fragment=\"1\"\u003erequiring a local visual indicator. A purpose-made back box is available as a\u003cbr data-mce-fragment=\"1\"\u003ecomplete unit.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806538383705,"sku":"","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/SquareRI.jpg?v=1707676603"},{"product_id":"copy-of-square-remote-indicator-2500226","title":"FireClass 601RIL - Remote Indicator - 540.003.006","description":"\u003cp\u003eThe 601RIL Remote Indicator is used where a detector LED is not visible i.e.,\u003cbr\u003ewhen the detector is mounted in a roof void, lift shaft etc.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eGeneral Features\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e- Dimensions (WxHxD): 86x86x16 mm.\u003cbr\u003e- Operating Temperature: -20 to +70 °C.\u003cbr\u003e- Storage Temperature: -45 to +80 °C.\u003cbr\u003e- Relative Humidity: 95% (non condensing).\u003cbr\u003e- Current consumption Standby: 0 Alarm: 5.43 mA.\u003c\/p\u003e\n\u003cp\u003eSupplied as face plate only, does not include back box.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806538514777,"sku":"540.003.006","price":10.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/REMOTEINDICATOR-802470.jpg?v=1713277429"},{"product_id":"fireclass-bxm24-25-u-en54-power-supply-unit-508-031-744","title":"FireClass BXM24\/25-U - EN54 Power Supply Unit - 508.031.744","description":"\u003cp\u003eThe BXM24\/25-U and 50-U are approved by IMQ to EN 54-4:1997 + A1:2002 and\u003cbr data-mce-fragment=\"1\"\u003eEN60950-1:2001. The steel housing contains a 2.5 amp or 5 amp switch mode\u003cbr data-mce-fragment=\"1\"\u003epower supply and monitoring board and has space to accommodate 2 x 12V 17Ah\u003cbr data-mce-fragment=\"1\"\u003esealed lead acid batteries.\u003c\/p\u003e\n\u003cp\u003eThe 10 front panel LED’s comprehensively indicate the status of the unit.\u003c\/p\u003e\n\u003cp\u003e- Robust metal housing.\u003cbr\u003e- Twin fused outputs.\u003cbr\u003e- Temperature compensated charging.\u003cbr\u003e- Deep discharge protection of batteries.\u003cbr\u003e- Fault relay output.\u003cbr\u003e- Size 383mm wide x 408mm high x 97mm deep.\u003cbr\u003e- Weight 4.3 Kg (excluding batteries).\u003cbr\u003e- Supply voltage 230VAC 50\/60Hz.\u003cbr\u003e- Comprehensive LED status indication.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806542545241,"sku":"508.031.744","price":154.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/BXM24-50-B-934092.jpg?v=1713277429"},{"product_id":"copy-of-fireclass-bxm24-25-u-en54-power-supply-unit-508-031-744","title":"FireClass BXM24\/50-U - EN54 Power Supply Unit - 508.031.745","description":"\u003cp\u003eThe BXM24\/25-U and 50-U are approved by IMQ to EN 54-4:1997 + A1:2002 and\u003cbr data-mce-fragment=\"1\"\u003eEN60950-1:2001. The steel housing contains a 2.5 amp or 5 amp switch mode\u003cbr data-mce-fragment=\"1\"\u003epower supply and monitoring board and has space to accommodate 2 x 12V 17Ah\u003cbr data-mce-fragment=\"1\"\u003esealed lead acid batteries.\u003c\/p\u003e\n\u003cp\u003eThe 10 front panel LED’s comprehensively indicate the status of the unit.\u003c\/p\u003e\n\u003cp\u003e- Robust metal housing.\u003cbr\u003e- Twin fused outputs.\u003cbr\u003e- Temperature compensated charging.\u003cbr\u003e- Deep discharge protection of batteries.\u003cbr\u003e- Fault relay output.\u003cbr\u003e- Size 383mm wide x 408mm high x 97mm deep.\u003cbr\u003e- Weight 4.3 Kg (excluding batteries).\u003cbr\u003e- Supply voltage 230VAC 50\/60Hz.\u003cbr\u003e- Comprehensive LED status indication.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806542643545,"sku":"508.031.745","price":188.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/BXM_7c238d9a-4cbb-4e52-b7a9-cbe1968ad8de-394208.jpg?v=1713277429"},{"product_id":"fireclass-801hl-remote-led-indicator-516-800-909","title":"FireClass 801HL - Remote LED Indicator - 516.800.909","description":"\u003cp\u003eThe 801HL Remote Indicator is used where a detector LED is not visible i.e., when\u003cbr data-mce-fragment=\"1\"\u003ethe detector is mounted in a roof void, lift shaft etc.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe 801HL remote indicator lamp provides a larger indicator for use in place of the\u003cbr data-mce-fragment=\"1\"\u003eRIL when longer distances are involved or in VdS influenced markets. Typically\u003cbr data-mce-fragment=\"1\"\u003eused to indicate the source of an alarm in buildings with long corridors eg. hotels,\u003cbr data-mce-fragment=\"1\"\u003ehospitals, apartments.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":47806550081881,"sku":"516.800.909","price":9.52,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/801HL-172533.jpg?v=1713277430"},{"product_id":"fireclass-essential-2-zone-panel","title":"FireClass Essential 2 Zone Panel - 508.032.730","description":"\u003cp\u003eFireClass Essential Panels are EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants. The panels can support up to 128 devices with a maximum of 32 devices on each zone. The panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost EN54-2, EN54-4 approved panel\u003c\/li\u003e\n\u003cli\u003eListed as part of the EN54-13 system certificate\u003c\/li\u003e\n\u003cli\u003eAvailable in 2 zone and 4 zone versions\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e 508.032.730 Datasheet\u003c\/h2\u003e\n\n\u003cp\u003e\u003ca style=\"color: red;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.730_508.032.731_508.032.732_508.032.733.pdf?v=1786013920\"\u003e\u003cb\u003eDownload 508.032.730 Datasheet\u003cb\u003e\u003c\/b\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57049864274265,"sku":"508.032.730","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.730_FC_Essential_2_Zone_Panel.jpg?v=1786014104"},{"product_id":"fireclass-essential-4-zone-panel","title":"FireClass Essential 4 Zone Panel - 508.032.731","description":"\u003cp\u003eFireClass Essential Panels are EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants. The panels can support up to 128 devices with a maximum of 32 devices on each zone. The panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost EN54-2, EN54-4 approved panel\u003c\/li\u003e\n\u003cli\u003eListed as part of the EN54-13 system certificate\u003c\/li\u003e\n\u003cli\u003eAvailable in 2 zone and 4 zone versions\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e 508.032.731 Datasheet\u003c\/h2\u003e\n\n\u003cp\u003e\u003ca style=\"color: red;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.730_508.032.731_508.032.732_508.032.733.pdf?v=1786013920\"\u003e\u003cb\u003eDownload 508.032.731 Datasheet\u003cb\u003e\u003c\/b\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57050370146649,"sku":"508.032.731","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.731_FC_Essential_4_Zone_Panel.jpg?v=1786014104"},{"product_id":"fireclass-essential-4-zone-panel-main-system-board","title":"FireClass Essential 4 Zone Panel Main System Board - 508.032.732","description":"\u003cp\u003eFireClass Essential Panels are EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants. The panels can support up to 128 devices with a maximum of 32 devices on each zone. The panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost EN54-2, EN54-4 approved panel\u003c\/li\u003e\n\u003cli\u003eListed as part of the EN54-13 system certificate\u003c\/li\u003e\n\u003cli\u003eAvailable in 2 zone and 4 zone versions\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e 508.032.732 Datasheet\u003c\/h2\u003e\n\n\u003cp\u003e\u003ca style=\"color: red;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.730_508.032.731_508.032.732_508.032.733.pdf?v=1786013920\"\u003e\u003cb\u003eDownload 508.032.732 Datasheet\u003cb\u003e\u003c\/b\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57050376470873,"sku":"508.032.732","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.732_FC_Essential_4zon_Motherboard.jpg?v=1786014104"},{"product_id":"fireclass-essential-2-zone-panel-main-system-board","title":"FireClass Essential 2 Zone Panel Main System Board - 508.032.733","description":"\u003cp\u003eFireClass Essential Panels are EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants. The panels can support up to 128 devices with a maximum of 32 devices on each zone. The panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost EN54-2, EN54-4 approved panel\u003c\/li\u003e\n\u003cli\u003eListed as part of the EN54-13 system certificate\u003c\/li\u003e\n\u003cli\u003eAvailable in 2 zone and 4 zone versions\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e 508.032.733 Datasheet\u003c\/h2\u003e\n\n\u003cp\u003e\u003ca style=\"color: red;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.730_508.032.731_508.032.732_508.032.733.pdf?v=1786013920\"\u003e\u003cb\u003eDownload 508.032.733 Datasheet\u003cb\u003e\u003c\/b\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57050379518297,"sku":"508.032.733","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.032.733_FC_Essential_2zon_Motherboard.jpg?v=1786014105"},{"product_id":"motherboard-for-fireclass-prescient-iii","title":"Motherboard for FireClass Prescient III - 2605183","description":"\u003ch2\u003eSpare Motherboard for FireClass Prescient III\u003c\/h2\u003e\n\u003cp\u003eFireClass Essential Panels are EN-approved, low cost conventional panels that are available in both 2 Zone and 4 Zone variants. The panels can support up to 128 devices with a maximum of 32 devices on each zone. The panels are approved to EN 54-2, EN 54-4, and listed as part of the EN 54-13 system certificate.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost EN54-2, EN54-4 approved panel\u003c\/li\u003e\n\u003cli\u003eListed as part of the EN54-13 system certificate\u003c\/li\u003e\n\u003cli\u003eAvailable in 2 zone and 4 zone versions\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eModern and aesthetic design\u003c\/li\u003e\n\u003cli\u003eSurface mountable\u003c\/li\u003e\n\u003cli\u003eOption to set delays for outputs during alarm\u003c\/li\u003e\n\u003cli\u003eButtons for silence, resound, and reset\u003c\/li\u003e\n\u003cli\u003eTwo open collector outputs\u003c\/li\u003e\n\u003cli\u003eDisable feature for sounders and zones\u003c\/li\u003e\n\u003cli\u003eVolt-free fire and fault relays\u003c\/li\u003e\n\u003cli\u003eTest feature for installation\u003c\/li\u003e\n\u003cli\u003eTwo auxiliary inputs: alert input and class change input\u003c\/li\u003e\n\u003cli\u003eSupport for all FireClass 600 and 700 series conventional detectors, conventional sounders, and VADs\u003c\/li\u003e\n\u003cli\u003eSupport for third party devices\u003c\/li\u003e\n\u003cli\u003eFully compliant with EN 54-2, EN 54-4, and is listed as part of the EN 54-13 system certificate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57050444824921,"sku":"2605183","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/Image_placeholders__Fireclass.png?v=1768243377"},{"product_id":"mub-rv-universal-5-base-with-relay","title":"MUB-RV Universal 5” Base With Relay - 508.031.751","description":"\u003cp\u003eThe 5B is the most common base designed to fix directly to the ceiling or various common backboxes. This base allows a detector to be plugged in directly.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVariety of fixing options.\u003c\/li\u003e\n\u003cli\u003eRemote LED connections.\u003c\/li\u003e\n\u003cli\u003ePark position and address flag holder.\u003c\/li\u003e\n\u003cli\u003eIntegral breakout locking key.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067057906009,"sku":"508.031.751","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/508.031.751_MUB-RV_Universal_5in_base_with_relay.jpg?v=1786014104"},{"product_id":"protective-cage-for-high-base","title":"Protective Cage for High Base - 517.050.011","description":"\u003cp\u003eWhite powder coated steel protective cage for Series FC400 Detectors fitted with a sounder base.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120mm dia x 80mm deep.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067068588377,"sku":"517.050.011","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/517.050.011_Protective_Cage_for_high_base.jpg?v=1786014104"},{"product_id":"4b-em-euro-mount-isolator-base","title":"4B-EM Euro Mount Isolator Base - 517.050.052","description":"\u003cp\u003eThe euro-mounting base provides a matching back box, which allows the 5” bases to be ceiling mounted with conduit entries for standard 18 and 21mm conduit.\u003c\/p\u003e\n\u003ch2\u003eGeneral Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 x 18mm conduit entries.\u003c\/li\u003e\n\u003cli\u003e2 x 21mm conduit entries.\u003c\/li\u003e\n\u003cli\u003eFits all 4” bases.\u003c\/li\u003e\n\u003cli\u003eAccepts up to 8 accessory terminals.\u003c\/li\u003e\n\u003cli\u003eBase Accessory terminal kit (pack of 10) part number 517.050.612.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067093950809,"sku":"517.050.052","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/517.050.052_4B-EM_Euro_Mount.jpg?v=1786014104"},{"product_id":"fc420cpb-mount-back-box-for-fc420cp-i","title":"FC420CPB Mount Back Box for FC420CP-I - 10-115","description":"\u003cp\u003eMount Back Box for FC420CP-I with terminals.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067105059161,"sku":"10-115","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/10-115_Callpoint_surface_mount_back_box_for_FC420.jpg?v=1786014104"},{"product_id":"conventional-manual-call-point-with-glass-c-w-back-box","title":"Conventional Manual Call Point with Glass c\/w Back Box - 2501013","description":"\u003cp\u003eConventional manual alarm call point with integral alarm LED and activation resistor. Operation is by break glass. This call point is semi flush mounted or can be surface mounted using back box 515.001.021 or 10-115, and comes with a test key.\u003c\/p\u003e\n\u003ch2\u003e 2501013 Datasheet\u003c\/h2\u003e\n\n\u003cp\u003e\u003ca style=\"color: red;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/2501013.pdf?v=1786013921\"\u003e\u003cb\u003eDownload 2501013 Datasheet\u003cb\u003e\u003c\/b\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/p\u003e\n","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067110662489,"sku":"2501013","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/2501013_Conventional_Manual_Call_Point_with_Glass_Element_with_back_box.jpg?v=1786014104"},{"product_id":"back-box-10-115-back-box-sr2-t-sus528w","title":"Back Box 10-115 - Back Box SR2-T SUS528W - Back Box for Manual Call Point - 515.001.021","description":"\u003cp\u003eConventional manual alarm call point with integral alarm LED and activation resistor. Operation is by break glass. This call point is semi flush mounted or can be surface mounted using back box 515.001.021 or 10-115, and comes with a test key.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067126391129,"sku":"515.001.021","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/515.001.021_Standard_Back_box_for_manual_call_point.jpg?v=1786014104"},{"product_id":"spare-manual-call-point-keys-pack-of-10","title":"Spare Manual Call Point Keys (Pack of 10) - 515.001.045","description":"\u003cp\u003eTest key for all MCP and CP style callpoints.\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067129209177,"sku":"515.001.045","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/515.001.045_Spare_Manual_callpoint_Keys.jpg?v=1786014104"},{"product_id":"spare-plastic-element-for-manual-call-point","title":"Spare Plastic Element for Manual Call Point (Pack of 5) - 515.001.119","description":"\u003cp\u003eEN54 Part 11 Spare Plastic for Callpoints (Pack of 5).\u003c\/p\u003e","brand":"FireClass","offers":[{"title":"Default Title","offer_id":57067132453209,"sku":"515.001.119","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/files\/Image_placeholders__Fireclass.png?v=1768243377"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0793\/3788\/1945\/collections\/FireClass_Product_Range_Montage.jpg?v=1755086364","url":"https:\/\/ifp-uk.com\/collections\/fire-detection.oembed?page=2","provider":"International Fire Protection","version":"1.0","type":"link"}